2024/11/12 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:154 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- BAY CHECK GC @ 170610 2024/11/11 0.5795 1.01563 1.2308 00.3856 00.0000 00.0000 96.2347 02.0168 00.1129 00.0066 00.0077 00.0000 00.0018 00.0010 00.0008 00.0006 00.0002 00.0000 CUSTER ST @ LINE AD ST1 2024/11/11 0.5695 1.00903 0.3832 01.1290 00.0000 00.0000 97.2358 01.1981 00.0474 00.0019 00.0041 00.0000 00.0001 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2024/11/11 0.5913 1.03536 0.7983 00.9720 00.0000 00.0000 93.3865 04.6400 00.1758 00.0078 00.0121 00.0000 00.0024 00.0019 00.0012 00.0009 00.0004 00.0000 CHANDLER ST DISCHARGE G 2024/11/11 0.5886 1.03454 0.6749 00.9608 00.0000 00.0000 93.7524 04.4489 00.1457 00.0057 00.0067 00.0000 00.0013 00.0010 00.0009 00.0007 00.0003 00.0000 FM 63 - Columbia GC @ 2 2024/11/08 0.5998 1.07306 0.1964 00.4287 00.0000 00.0000 91.3470 07.6549 00.3075 00.0202 00.0335 00.0000 00.0052 00.0023 00.0018 00.0013 00.0006 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.